0.3µm Primary purification rate of particulate matter
No. | Wind speed m/s | Primary purification rate % |
1 | 1.0 | 99.9 |
2 | 2.0 | 99.8 |
3 | 3.0 | 99.7 |
4 | 4.0 | 99.5 |
0.25µm Primary purification rate of particulate matter
No. | Wind speed m/s | Primary purification rate % |
1 | 1.0 | 100 |
2 | 2.0 | 100 |
3 | 3.0 | 100 |
4 | 4.0 | 100 |
5 advantages enjoy every moment
PM2.5、CO2、VOC、Show the PM2.5、CO2、VOC
Show the humidity、temperature and time automatically
Manual mode
Clock control mode
Sensor control mode
Free setting, free purification Set on/off 8 times /day from Monday to Sunday One key setting, purification by yourself Sensor Mode Automatic detection of indoor air pollution degree, automatic operation of equipment according to pollution degree Control by nature and purify all the times Manual choose work mode and wind speed. Perfect circulation air duct, 360 〬 all-round purification New electrostatic adsorption device Breaking the traditional production technology of electrostatic adsorption device, using non-metallic materials to make micro power consumption adsorption device and low-voltage polarizer, and supporting the combination of driving circuit. The adsorption device not only has a significant effect on adsorbing fine particles, but also overcomes the shortcomings of ozone and arc climbing caused by metal electrostatic dust. Staphylococcus albTest conclusion: 1. Under the condition of test temperature 20 ~ 25 ℃ and relative humidity of 40-60%, the killing rate of Staphylococcus albus is 99.98% ,after artificially sprayed in the air of 20m3 airtight room in 90 minutes, and the natural decay rate of this bacterium is 45.45%, which meets the requirements of technical code for disinfection (2002) 2. Natural bacteria: Results: under the condition of ambient temperature 20-24 ℃ , relative humidity 40-56% natural bacteria decay rate 98.78%in the air of 100 m3 in closed room after 90 minutes' . PM2.5 purification Rate: No. Detection subject Unit Time Pollutant concentration Result PM2.5 purification rate % 0 0.863mg/m3 99.8 20mins 0.002 mg/m3 Ozone concentration No. Detection subject Unit Standard Result Judge 1 Ozone concentration(outlet 5cm point) mg/m3 <=10 0.002 Qualified Standby power W <=2.0 0.8 Qualified Application: It is suitable for hospital surgey room, delivery room, monitoring room, newborn room, burn ward, intervention, isolation ward, supply room, hemodialysis, treatment room, Stomatology, infectious ward, etc.; biological laboratory, food and drug production workshop, banking system, school, library and other environments with high requirements for air quality